If you have an…
Then…
AFF A800 or ASA A800
HA pair
The substeps assume the existing shelf is cabled to RoCE
capable PCIe cards in slot 5 on each controller.
If needed, you can reference cabling illustrations showing an
existing single shelf and the recabled shelf, in a two shelf
configuration.
Cable a hot-add shelf for an AFF A800 or ASA A800HA pair
a. On controller A, move the cable from slot 5 port 2 (e5b) to slot 3 port 2
(e3b).
b. Repeat the same cable move on controller B.
AFF A400 or ASA A400
HA pair
If needed, you can reference cabling illustrations showing an
existing single shelf and the recabled shelf, in a two shelf
configuration.
Cable a hot-add shelf for an AFF A400 or ASA A400HA pair
a. On controller A, move the cable from port e0d to slot 5 Port 2 (e5b).
b. Repeat the same cable move on controller B.
2. Verify that the recabled shelf is cabled correctly.
If any cabling errors are generated, follow the corrective actions provided.
NetApp Downloads: Config Advisor
Prepare to manually assign drive ownership for a hot-add
If you are manually assigning drive ownership for the NS224 drive shelf you are hot-
adding, then you need to disable automatic drive assignment if it is enabled.
Before you begin
You must have met the system requirements.
About this task
You need to manually assign drive ownership if drives in the shelf will be owned by both controller modules in
the HA pair.
Steps
1. Verify whether automatic drive assignment is enabled:
storage disk option show
You can enter the command on either controller module.
1497
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...