Possible loss of data access:
Never slam the drawer shut. Push the drawer in slowly
to avoid jarring the drawer and causing damage to the storage array.
h. Close the drive drawer by pushing both levers towards the center.
i. Repeat these steps for each drawer in the disk shelf.
4. If you are adding multiple disk shelves, repeat the previous steps for each disk shelf you are installing.
5. Connect the power supplies for each disk shelf:
a. Connect the power cords first to the disk shelves, securing them in place with the power cord retainer,
and then connect the power cords to different power sources for resiliency.
b. Turn on the power supplies for each disk shelf and wait for the disk drives to spin up.
6. Set the shelf ID for each shelf you are hot-adding to an ID that is unique within the HA pair or single-
controller configuration.
A valid shelf ID is 00 through 99. It is recommended that you set the shelf IDs so that IOM6 shelves use
lower numbers (1 - 9) and IOM12 shelves use higher numbers (10 and greater).
If you have a platform model with onboard storage, shelf IDs must be unique across the internal shelf and
externally attached shelves. It is recommended that you set the internal shelf to 0. In MetroCluster IP
configurations, only the external shelf names apply, and therefore the shelf names do not need to be
unique.
a. If needed, verify shelf IDs already in use by running Active IQ Config Advisor.
NetApp Downloads: Config Advisor
You can also run the
storage shelf show -fields shelf-id
command to see a list of shelf IDs
already in use (and duplicates if present) in your system.
b. Access the shelf ID button behind the left end cap.
c. Change the first number of the shelf ID by pressing and holding the orange button until the first number
on the digital display blinks, which can take up to three seconds.
d. Press the button to advance the number until you reach the desired number.
e. Repeat substeps c and d for the second number.
f. Exit the programming mode by pressing and holding the button until the second number stops blinking,
which can take up to three seconds.
1566
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...