9. If you are replacing another disk drive, repeat Steps 3 through 8.
10. Verify the disk drive’s activity (green) LED is illuminated.
When the disk drive’s activity LED is solid green, it means the disk drive has power. When the disk drive’s
activity LED is blinking, it means the disk drive has power and I/O is in progress. If the disk drive firmware
is automatically updating, the LED will be blinking.
11. If you disabled automatic drive assignment in Step 1, manually assign disk ownership, and then reenable
automatic drive assignment if needed:
a. Display all unowned disks:
storage disk show -container-type unassigned
b. Assign each disk:
storage disk assign -disk
disk_name
-owner
owner_name
You can use the wildcard character to assign more than one disk at once.
c. Reenable automatic drive assignment if needed:
storage disk option modify -node
node_name
-autoassign on
You need to reenable automatic drive assignment on both controllers in an HA pair.
12. Return the failed part to NetApp, as described in the RMA instructions shipped with the kit.
Contact technical support at
, 888-463-8277 (North America), 00-800-44-638277 (Europe),
or +800-800-80-800 (Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
Hot-swap a disk drive in a DS460C disk shelf - shelves with IOM12 modules
You can hot-swap a failed disk drive in a DS460C disk shelf.
Before you begin
• The replacement disk drive must be supported by the DS460C disk shelf.
• All other components in the system must be functioning properly; if not, contact technical support.
• The disk drive you are removing must be failed.
You can verify the disk drive is failed by running the
storage disk show -broken
command. The
failed disk drive appears in the list of failed disk drives. If it does not, you should wait, and run the
command again.
Depending on the disk drive type and capacity, it can take up to several hours for the disk
drive to appear in the list of failed disk drives.
• If you are replacing a self-encrypting disk (SED), you must follow the instructions for Replacing an SED in
the ONTAP documentation for your version of ONTAP.
Instructions in the ONTAP documentation describe additional steps you must perform before and after
replacing an SED.
NetApp encryption overview with the CLI
1616
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...