If any interfaces are listed as
false
, revert those interfaces back to their home port using the
net int
revert
command.
7. Move the console cable to the target node and run the
version -v
command to check the ONTAP
versions.
8. Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
9. Use the
storage encryption disk show
at the clustershell prompt, to review the output.
10. Use the
security key-manager key query
command to display the key IDs of the authentication
keys that are stored on the key management servers.
◦
If the
Restored
column =
yes/true
, you are done and can proceed to complete the replacement
process.
◦
If the
Key Manager type
=
external
and the
Restored
column = anything other than
yes/true
,
use the
security key-manager external restore
command to restore the key IDs of the
authentication keys.
If the command fails, contact Customer Support.
◦
If the
Key Manager type
=
onboard
and the
Restored
column = anything other than
yes/true
,
use the
security key-manager onboard sync
command to re-sync the Key Manager type.
Use the security key-manager key query to verify that the
Restored
column =
yes/true
for all
authentication keys.
11. Connect the console cable to the partner node.
12. Give back the node using the
storage failover giveback -fromnode local
command.
13. Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Return the failed part to NetApp - AFF A300
After you replace the part, you can return the failed part to NetApp, as described in the
RMA instructions shipped with the kit. Contact technical support at
, 888-
463-8277 (North America), 00-800-44-638277 (Europe), or +800-800-80-800
(Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
Chassis
Replace the chassis - AFF A300
To replace the chassis, you must move the power supplies, fans, and controller modules
from the impaired chassis to the new chassis, and swap out the impaired chassis from
the equipment rack or system cabinet with the new chassis of the same model as the
impaired chassis.
All other components in the system must be functioning properly; if not, you must contact technical support.
300
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...