If your system is in…
Then perform these steps…
A stand-alone
configuration
a. With the cam handle in the open position, firmly push the controller module in
until it meets the midplane and is fully seated, and then close the cam handle
to the locked position.
Do not use excessive force when sliding the controller module
into the chassis to avoid damaging the connectors.
b. If you have not already done so, reinstall the cable management device.
c. Bind the cables to the cable management device with the hook and loop
strap.
d. Reconnect the power cables to the power supplies and to the power sources,
turn on the power to start the boot process, and then press
Ctrl-C
after you
see the
Press Ctrl-C for Boot Menu
message.
If you miss the prompt and the controller module boots to
ONTAP, enter
halt
, and then at the LOADER prompt enter
boot_ontap
, press
Ctrl-C
when prompted, and then boot to
Maintenance mode.
e. From the boot menu, select the option for Maintenance mode.
Step 5: Run system-level diagnostics
After installing a new DIMM, you should run diagnostics.
What you’ll need
Your system must be at the LOADER prompt to start System Level Diagnostics.
About this task
All commands in the diagnostic procedures are issued from the node where the component is being replaced.
Steps
1. If the node to be serviced is not at the LOADER prompt, perform the following steps:
a. Select the Maintenance mode option from the displayed menu.
b. After the node boots to Maintenance mode, halt the node:
halt
After you issue the command, you should wait until the system stops at the LOADER prompt.
During the boot process, you can safely respond
y
to prompts:
▪
A prompt warning that when entering Maintenance mode in an HA configuration, you must ensure
that the healthy node remains down.
2. At the LOADER prompt, access the special drivers specifically designed for system-level diagnostics to
function properly:
boot_diags
During the boot process, you can safely respond
y
to the prompts until the Maintenance mode prompt (*>)
55
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...