node1_siteA::> metrocluster node show -fields configuration-state
dr-group-id cluster node configuration-state
----------- ---------------------- --------------
-------------------
1 node1_siteA node1mcc-001 configured
1 node1_siteA node1mcc-002 configured
1 node1_siteB node1mcc-003 configured
1 node1_siteB node1mcc-004 configured
4 entries were displayed.
11. Verify the operation of the MetroCluster configuration in Data ONTAP:
a. Check for any health alerts on both clusters:
system health alert show
b. Confirm that the MetroCluster is configured and in normal mode:
metrocluster show
c. Perform a MetroCluster check:
metrocluster check run
d. Display the results of the MetroCluster check:
metrocluster check show
e. Run Config Advisor. Go to the Config Advisor page on the NetApp Support Site at
support.netapp.com/NOW/download/tools/config_advisor/
After running Config Advisor, review the tool’s output and follow the recommendations in the
output to address any issues discovered.
12. Simulate a switchover operation:
a. From any node’s prompt, change to the advanced privilege level:
set -privilege advanced
You need to respond with
y
when prompted to continue into advanced mode and see the
advanced mode prompt (*>).
b. Perform the switchback operation with the -simulate parameter:
metrocluster switchover
-simulate
c. Return to the admin privilege level:
set -privilege admin
Step 6: Restore Storage and Volume Encryption functionality
After replacing the controller module or NVRAM module for a storage system that you
previously configured to use Storage or Volume Encryption, you must perform additional
steps to provide uninterrupted Encryption functionality. You can skip this task on storage
systems that do not have Storage or Volume Encryption enabled.
Step
1. Restore Storage or Volume Encryption functionality by using the appropriate procedure in
Encryption overview with the CLI
Use one of the following procedures, depending on whether you are using onboard or external key
725
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...