9. Although the environment variables and bootargs are retained, you should check that all required boot
environment variables and bootargs are properly set for your system type and configuration using the
printenv bootarg name
command and correct any errors using the
setenv variable-name
<value>
command.
a. Check the boot environment variables:
▪
bootarg.init.boot_clustered
▪
partner-sysid
▪
bootarg.init.flash_optimized
for AFF C190/AFF A220 (All Flash FAS)
▪
bootarg.init.san_optimized
for AFF A220 and All SAN Array
▪
bootarg.init.switchless_cluster.enable
b. If External Key Manager is enabled, check the bootarg values, listed in the
kenv
ASUP output:
▪
bootarg.storageencryption.support <value>
▪
bootarg.keymanager.support <value>
▪
kmip.init.interface <value>
▪
kmip.init.ipaddr <value>
▪
kmip.init.netmask <value>
▪
kmip.init.gateway <value>
c. If Onboard Key Manager is enabled, check the bootarg values, listed in the
kenv
ASUP output:
▪
bootarg.storageencryption.support <value>
▪
bootarg.keymanager.support <value>
▪
bootarg.onboard_keymanager <value>
d. Save the environment variables you changed with the
savenv
command
e. Confirm your changes using the
printenv
variable-name
command.
10. From the LOADER prompt, boot the recovery image from the USB flash drive:
boot_recovery
The image is downloaded from the USB flash drive.
11. When prompted, either enter the name of the image or accept the default image displayed inside the
brackets on your screen.
12. After the image is installed, start the restoration process:
a. Record the IP address of the impaired node that is displayed on the screen.
b. Press
y
when prompted to restore the backup configuration.
c. Press
y
when prompted to confirm that the backup procedure was successful.
13. Press
y
when prompted whether to use the restored copy, and then press
y
when prompted to reboot the
node.
14. From the partner node in advanced privilege level, start the configuration synchronization using the IP
address recorded in the previous step:
system node restore-backup -node local -target
-address
impaired_node_IP_address
759
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...