15. After the configuration synchronization is complete without errors, press
y
when prompted to confirm that
the backup procedure was successful.
16. Press
y
when prompted whether to use the restored copy, and then press
y
when prompted to reboot the
node.
17. Verify that the environmental variables are set as expected.
a. Take the node to the LOADER prompt.
From the ONTAP prompt, you can issue the command system node halt -skip-lif-migration-before
-shutdown true -ignore-quorum-warnings true -inhibit-takeover true.
b. Check the environment variable settings with the
printenv
command.
c. If an environment variable is not set as expected, modify it with the
setenv
environment-
variable-name
changed-value
command.
d. Save your changes using the
savenev
command.
e. Reboot the node.
18. With the rebooted impaired node displaying the
Waiting for giveback…
message, perform a giveback
from the healthy node:
If your system is in…
Then…
An HA pair
After the impaired node is displaying the
Waiting for giveback…
message, perform a giveback from the healthy node:
a. From the healthy node:
storage failover giveback
-ofnode partner_node_name
The impaired node takes back its storage, finishes booting, and
then reboots and is again taken over by the healthy node.
If the giveback is vetoed, you can consider
overriding the vetoes.
ONTAP 9 High-Availability Configuration Guide
b. Monitor the progress of the giveback operation by using the
storage failover show-giveback command.
c. After the giveback operation is complete, confirm that the HA pair
is healthy and that takeover is possible by using the
storage
failover show
command.
d. Restore automatic giveback if you disabled it using the storage
failover modify command.
19. Exit advanced privilege level on the healthy node.
Boot the recovery image - AFF A700s
You must boot the ONTAP image from the USB drive, restore the file system, and verify
the environmental variables.
760
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...