60
NetApp AltaVault Cloud Integrated Storage Installation and Service Guide for Physical Appliances
Beta Draft
System maintenance
Migrating data from a SteelStore appliance to an AltaVault appliance
Migrating data from a SteelStore appliance to an AltaVault
appliance
For information on migrating data from an older physical appliance to the latest AltaVault appliance, see
NetApp
AltaVault Cloud Integrated Storage User’s Guide
,
Chapter 11 Migrating data from a SteelStore appliance to an
AltaVault appliance
.
Note:
There is no support for directly migrating or upgrading from 3.x to 4.1 appliances. You must first migrate to 4.0,4.0.0.1,or
4.0.1 and then upgrade to 4.1. This applies to both physical and virtual appliances.
Shutting down controllers
An AltaVault controller has field-replaceable units (FRUs) that are not hot-swappable. For a list of AltaVault system
FRUs, see
“Field replaceable units” on page 49
When you are replacing field-replaceable units (FRUs) that are not hot-swappable or when you are replacing the
controller itself, shut down the controller. A clean shutdown of the AltaVault controller ensures that all data has been
written to the storage subsystems. You must also disconnect power from the power supplies before these replacement
procedures.
To shut down a stand-alone AltaVault controller
1.
To shut down the AltaVault controller, enter the following CLI command:
CLI> reload halt
When the shutdown is successful, the box powers off, there are no prompts or output to the console.
2.
If
you
are not already grounded, properly ground
yourself
.
3.
Turn off the power supplies by turning the on/off switch to the OFF (O) position. If the power source for this power
supply has a on/off switch, turn the switch to the OFF (O) position.
4.
Unplug the power cords from the power supplies and the power source:
–
Pinch the tab on the locking mechanism of the cable retainer clip, and open the retainer clip.
–
Slide the retainer clip off the cord.
–
Unplug the power cord from the power supply. Then, unplug the cord from the power source.
–
Repeat Step 4 for the second power supply.
Replacing controllers
These instructions describe how to replace an AltaVault controller in the case of an RMA (Return Merchandise
Authorization).
Summary of Contents for AltaVault Cloud Integrated Storage 4.1