System maintenance
Hot-swapping controller fan modules
5.
Pull the fan module straight out from the chassis, as shown below. Make sure that you support the base of the fan
module with your free hand, so that it does not fall out of the chassis.
Note:
Controller fan modules are short. Always support the bottom of the module with your free hand, so that it does not suddenly
drop free from the chassis.
6.
Identify fan module components as described in this table:
7.
Set the failed fan module aside.
8.
Before removing another fan module from the chassis, install a replacement fan module using the steps described
in the procedure,
“Installing fan modules” on page 68
.
Installing fan modules
Before you begin, verify that the controller fan module that you are installing is supported by your controller model.
To install a fan module
1.
If
you
are not already grounded, properly
ground yourself
.
Component
Description
1
Cam handle
2
Fan module
3
Cam handle release latch
4
Fan module attention LED