1
Horizontal guide rail
2
Vertical guide rail
Attention:
Risk of equipment malfunction — Make sure to slide the connector into the guide rail. If the connector
rests on the top of the guide rail, problems might occur when the system runs.
d. Slide the vertical connector on the right cable chain into the vertical guide rail.
e. After you have reconnected both ends of the cable chain, carefully pull on the cable chain to verify that both connectors
are latched.
Attention:
Risk of equipment malfunction — If the connectors are not latched, the cable chain might come loose
during drawer operation.
4. Reinstall the right fan canister. If the drive shelf is receiving power, confirm that the amber LED on the back of the fan is
now off and that air is now coming out of the back.
The LED could remain on for as long as a minute after you reinstall the fan while the fan settles into the correct speed.
5. From the back of the drive shelf, remove the fan canister on the left side of the shelf.
6. If the shelf is powered on, ensure that the right fan goes to its maximum speed.
Attaching the cable chains
17