The interconnect tests are disabled by default and must be enabled to run separately.
5. Run the interconnect diagnostics test from the Maintenance mode prompt:
sldiag device run -dev
interconnect
You only need to run the interconnect test from one controller.
6. Verify that no hardware problems resulted from the replacement of the chassis:
sldiag device status
-dev interconnect -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of
failures resulting from testing the component.
7. Proceed based on the result of the preceding step.
If the system-level diagnostics
tests…
Then…
Were completed without any
failures
a. Clear the status logs:
sldiag device clearstatus
b. Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit Maintenance mode on both controllers:
halt
The system displays the LOADER prompt.
You must exit Maintenance mode on both
controllers before proceeding any further.
d. Enter the following command on both controllers at the LOADER
prompt:
bye
e. Return the controller to normal operation:
If your system is running
ONTAP…
Then…
With two nodes in the cluster
Issue these commands:
node::> cluster ha modify
-configured true``node::> storage failover modify
-node node0 -enabled true
With more than two nodes in the
cluster
Issue this command:
node::> storage failover modify
-node node0 -enabled true
In a two-node MetroCluster
configuration
Proceed to the next step. The MetroCluster switchback procedure is
done in the next task in the replacement process.
58