If your system has…
Then…
No network connection and is in a
MetroCluster IP configuration
a. Press
n
when prompted to restore the backup configuration.
b. Reboot the system when prompted by the system.
c. Wait for the iSCSI storage connections to connect.
You can proceed after you see the following messages:
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_auxiliary, address: ip-address).
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_partner, address: ip-address).
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_auxiliary, address: ip-address).
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_partner, address: ip-address).
d. Select the
Update flash from backup config
(sync flash) option
from the displayed menu.
If you are prompted to continue with the update, press
y
.
4. Ensure that the environmental variables are set as expected:
a. Take the controller to the LOADER prompt.
b. Check the environment variable settings with the
printenv
command.
c. If an environment variable is not set as expected, modify it with the
setenv
environment-
variable-name
changed-value
command.
d. Save your changes using the
savenv
command.
5. The next depends on your system configuration:
◦
If your system has onboard keymanager, NSE or NVE configured, go to
15