7. At the Boot Menu select the option for Normal Boot.
The system boots to
Waiting for giveback…
prompt.
8. Move the console cable to the partner controller and login as admin.
9. Confirm the target controller is ready for giveback with the
storage failover show
command.
10. Give back only the CFO aggregates with the storage failover giveback
-fromnode local -only-cfo
-aggregates true
command.
◦
If the command fails because of a failed disk, physically disengage the failed disk, but leave the disk in
the slot until a replacement is received.
◦
If the command fails because of an open CIFS session, check with the customer on how to close out
CIFS sessions.
Terminating CIFS can cause loss of data.
◦
If the command fails because the partner is "not ready", wait 5 minutes for the NVMEMs to
synchronize.
◦
If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the process. See
the appropriate Documentation Center for more information.
11. Once the giveback completes, check the failover and giveback status with the
storage failover show
and
`storage failover show
-giveback` commands.
Only the CFO aggregates (root aggregate and CFO style data aggregates) will be shown.
12. Move the console cable to the target controller.
13. If you are running ONTAP 9.5 and earlier, run the key-manager setup wizard:
a. Start the wizard using the
security key-manager setup -nodenodename
command, and then
enter the passphrase for onboard key management when prompted.
215