1. Check the NVMEM LED:
◦
If your system is in an HA configuration, go to the next step.
◦
If your system is in a stand-alone configuration, cleanly shut down the controller module, and then
check the NVRAM LED identified by the NV icon.
The NVRAM LED blinks while destaging contents to the flash memory when you halt the
system. After the destage is complete, the LED turns off.
▪
If power is lost without a clean shutdown, the NVMEM LED flashes until the destage is complete,
and then the LED turns off.
▪
If the LED is on and power is on, unwritten data is stored on NVMEM.
This typically occurs during an uncontrolled shutdown after ONTAP has successfully booted.
2. Locate the NVMEM battery in the controller module.
3. Locate the battery plug and squeeze the clip on the face of the battery plug to release the plug from the
socket, and then unplug the battery cable from the socket.
4. Grasp the battery and press the blue locking tab marked PUSH, and then lift the battery out of the holder
and controller module.
5. Move the battery to the replacement controller module.
6. Loop the battery cable around the cable channel on the side of the battery holder.
247