Installing hardware
55
2.12. Point to point backplane
2.12.1. Removing the HDD Backplane (3.5” HDD SKU)
Prerequisite: Remove the HDDs. See ???. Remove the top cover. See ???.
1. Disconnect the following cables from the HDD BP:
Figure 2.51. HDD BP Connectors
a.
Device 0 Connector connect to HDD 0
b.
Device 1 Connector connect to HDD 1
c.
Device 2 Connector connect to HDD 2
d.
Device 3 Connector connect to HDD 3
e.
10 pin Power connector for BP with +12V, +5V, +3.3V
f.
IPMB connector lining to on board BMC controller FAN Speed
g.
SGPIO connector for HDD LED Decode.
h.
System FAN 0 for CPU 0 Block
i.
System FAN 1 for CPU 0 Block
j.
System FAN 2 for CPU 0 Block
k.
System FAN 3 for CPU 1 Block
l.
System FAN 4 for CPU 1 Block
m.
System FAN 5 for CPU 1 Block
2. Remove five (5) screws from the HDD backplane.
Figure 2.52. Removing the 3.5” HDD Backplane Screws
3. Remove the HDD backplane from the chassis.
Summary of Contents for Demos R130 M2
Page 1: ...Netberg Demos R130 M2 server...
Page 2: ...Netberg Demos R130 M2 server...
Page 11: ...Netberg Demos R130 M2 server xi 9 5 Aligning the Rails 222...
Page 14: ...1 Chapter 1 Netberg Demos R130 M2 server...
Page 31: ...Netberg Demos R130 M2 server 18 On HDD failure HDD Fault Amber Off No failure detected...
Page 32: ...19 Chapter 2 Installing hardware...
Page 57: ...Installing hardware 44 Figure 2 36 Installing the Air Duct...
Page 60: ...Installing hardware 47 Figure 2 40 Connecting the Fan Assembly Cables...
Page 143: ...130 Chapter 6 Server Management Software...
Page 169: ...156 Chapter 8 Web Graphical User Interface GUI for ESMS...
Page 230: ...217 Chapter 9 Rail Kit Assembly...
Page 236: ...223 Chapter 10 Troubleshooting...