Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver-
Administrative Access Commands
3-9
v1.0, February 2007
3.3.5 show serial
This command displays serial communication settings for the switch.
Format
show serial
Modes
Privileged EXEC
User EXEC
Serial Port Login
Timeout
(minutes)
Specifies the time, in minutes, of inactivity on a Serial port
connection, after which the Switch will close the connection.
Any numeric value between 0 and 160 is allowed, the factory
default is 5. A value of 0 disables the timeout.
Baud Rate (bps)
The default baud rate at which the serial port will try to con-
nect. The available values are 1200, 2400, 4800, 9600,
19200, 38400,57600, and 115200 baud. The factory default is
9600 baud.
Character Size
(bits)
The number of bits in a character. The number of bits is
always 8.
Flow Control
Whether Hardware Flow-Control is enabled or disabled.
Hardware Flow Control is always disabled.
Stop Bits
The number of Stop bits per character. The number of Stop
bits is always 1.
Parity Type
The Parity Method used on the Serial Port. The Parity
Method is always None.