NetGear Print Server Manual
Physical Port Selects which physical printer port the logical port is mapped into. Converts LF to LF+CRAdd a carriage
return (CR) every time the line feed (LF) character code is received by the print server when any print data
is sent to this logical port.
String Before
Job
Provides the control character string to send to the printer before the first character of the job is sent to the
printer. One example of such an application would be switching to landscape mode when printing to the
logical port. The character string must be in hexadecimal format as in these examples:
ASCII = [Esc]&l0O
Hexadecimal = 1B266C304F
ASCII = [Esc]&l1O
Hexadecimal = 1B266C314F
String After
Job
Provides the control character string to send to the printer after the last character of the job is sent to the
printer. The character string must be in hexadecimal format as illustrated in the String Before Job example
above.
Physical Port Tab
This tab allows you to set the "Handshake Signal" used for communication between the Print Server
73