Power 

90–240 V; 50/60 Hz; 10 A  

Switched outputs 

 10 A total / 10 A per output  

Fuse 

Integrated, non-resettable 

Internal consumption 

Max 3 W 

Output relay  

Micro-disconnection (µ) (resistive load), SPST 
1E5 switching cycles, max. 1.5 kV pulse voltage 
Switch heat and fire resistance class 1 

NETIO 4PS

 interfaces 

1x Ethernet RJ-45 10/100 Mbit/s 

Environment 

IP30, protection rating = class 1 
Operating temperature -20°C to +75°C 
Device rated for pollution degree 2.  
Designed for continuous operation in altitudes up to 
2000 m. 
Does not require additional cooling. 

 
 

 

Summary of Contents for PowerPDU 4PS

Page 1: ...QIG Quick Installation Guide PowerPDU 4PS QIG...

Page 2: ...Do not expose the device to strong vibrations 4 Unauthorized modifications may damage the device or cause a fire 5 Protect the device from liquids and excessive temperatures 6 Make sure the device do...

Page 3: ...ndicated on the box Front view 1 1x RJ45 LAN jack 2 Output LEDs lit green when the corresponding output is switched on 3 RJ45 LEDs device states yellow and green 4 Multifunction SETUP button Rear view...

Page 4: ...he device starts 3x flash when the internal system restarts SETUP button Switching all outputs Output test Press the SETUP button 3x rapidly If an output is On 1 it is switched off If all outputs are...

Page 5: ...starts NETIO Discover 5 For MS Windows find the NETIO Discover utility at our website and install it 6 In other operating systems Mac Linux the NETIO Discover multiplatform version written in JAVA can...

Page 6: ...6 WEB interface The default username password combination is admin admin...

Page 7: ...ection resistive load SPST 1E5 switching cycles max 1 5 kV pulse voltage Switch heat and fire resistance class 1 NETIO 4PS interfaces 1x Ethernet RJ 45 10 100 Mbit s Environment IP30 protection rating...

Page 8: ...declaration relates is in conformity with the essential requirements and other relevant requirements of the Directive 2006 95 EC The product mentioned above is in conformity with the following standa...

Page 9: ...eb password Username admin password admin Factory defaults When powering up the device press and hold the SETUP button approx 10 second until the RJ45 Yellow LED 3 times blink Installation utility To...

Reviews: