6
Specifications
Power (input)
100-240 V; 50/60 Hz; 16 A
Switched outputs
16 A in total / 10 A each output
Maximum line breaker
capacity
C16A
Fuse
Integrated, non-resettable
Internal consumption
Max 2 W
Output relay
Micro-
disconnection (µ) (resistive load), SPST
1E5 switching cycles, max. 1.5 kV pulse voltage
Switch heat and fire resistance class 1
Digital Input (DI)
1x Dry contact input (DI)
Aux. DC power 12V/0,05A max (+12V, GND)
Interfaces
1x Ethernet RJ-45 10/100 Mbit/s
Attention! Device connected over LAN must be
connected in network with same earth potential (PE).
Environment
IP30, protection rating = class 1
Operating temperature -
20°C to 65°C / 10A
-
20°C to 50°C / 16A
Device rated for pollution degree 2.
Permanent use in altitudes up to 2000 MASL (metres
above sea level).
Does not require additional cooling.