channel
below safe range
Temperature of a humidity sensor has dropped below safe range
in safe range
Temperature of a humidity sensor has returned to safe range
above safe range
Temperature of a humidity sensor has risen above safe range
Smoke (1W) 1..4 / any channel
Normal
Readings are normal
Alarm!
The sensor detected the smoke
off
The sensor (current in the loop) is switched off
failed
The sensor failure
IO line 1..4 / any channel
Log.0
Logic line level switched to 0
Log.1
Logical line level switched to 1
Relay 1...8 / any channel
off
The relay is off
on
The relay is on
Watchdog 1...8 / any channel
reset
The "
" module carried out the reset of the relay
Watchdog
suspense
The operation of the module is suspensed
restore
The operaion of the module is restored
Signal 1..4 / any channel
activation
The signal has been activated by logic. So, the rule of logic worked,
the output of it is the “Signal 1..4”. More details about the rules of
logic and, in particular, the signal can be found in the section
10.2. [DKSF 48.5 IU] How Can I Use the "LOGIC" Module?
Monitoring 220V
GSM
SMS not a command
Incoming SMS is not a command
SMS from unknown numbers
An incoming SMS from an unknown number (subject to the setting of
white lists of numbers). Read more about setting up white lists in the
section:
[ENG] 12.2. [DKSF 48.5 IU] I Need to Configure the Number
to Send SMS Notifications SMS-уведомлений. How Can I Do This?
The Description of notification methods:
The
method of
notification
The description
SMS
Arbitrary SMS notifications. At the beginning of the text of a custom SMS notification, you can specify up to four recipients by
specifying their phone numbers in square brackets, separated by commas. Numbers are indicated in the format "Countrycode
". There must be a space between the closing square bracket and the message text. For example,
OperatorcodeCustomernumber
"[+79130000001, +79130000002, +79130000003, +79130000004] Houston, we have a problem!"
If you do not specify the recipients, i.e. there are no square brackets at the beginning of the text, the SMS will be sent to the
numbers specified in the settings on the “
” page of the device’s web interface and marked with a “
” checkmark.
SMS
On
HTTP GET
The called URL of a third-party service or cloud application. In order to send these notifications, the following scheme is used:Net
destination server. Therefore, the destination server must be
accessed via a white address and access to it must be from the outside.
The sending of the email notification is carried out to the addresses specified on the "
" page. In a custom notification it is
possible to set the subject of the message in the "
" entry field (substitutions are possible) and the text of the email message
Subj
itself. The recipient cannot be set, messages are sent to the recipients specified on the "EMAIL" page.
You can put the information from the NetPing MIB branch related to the sensor, IO line, or the relay that caused the event in the custom
notification text. Format: { }, where N is the SNMP OID component located in front of the sensor index.
N
For example, the text of the SMS notification “{6} - {3} ({4}°C - {5}°C), {2}°C" for the temperature sensor includes the following information from
the NetPing MIB branch of the tree:
The
Substitution
The Complete OID of variable
value from NetPing MIB
The name of the variable value
from NetPing MIB
The Description