11
Opening housing cover:
DANGER
ATTENTION:
The AP 117 cover may only be opened by authorized specialists.
Slide screwdriver into the opening slit
and turn.
Flip cover open to the left side.
Connection:
-
Open housing cover as described
above.
-
The electronic timer
can now be
connected via the terminal strip.
The voltage is supplied via the power
connection block 1 and 2 (DC or AC),
terminal 3 PE (AC).
The output voltage is applied to the
terminals 4 and 5 (AC or DC), terminal
6 PE (AC).
Direct voltage
If direct voltage (DC) is applied to the
terminals 1 and 2, direct voltage (DC) is
also applied to the terminals 4 and 5.
Alternating voltage
If alternating voltage (AC) is applied to
the terminals 1 and 2, alternating voltage
(AC) is also applied to the terminals 4
and 5.
If alternating voltage is applied, the pro-
tective conductor PE must always be
connected (terminals 3 and 6).