15
IMPORTANT
A cycle has to consist of at least two clock duty times and one clock pause
time.
IMPORTANT
The total sum of clock duty times and clock pause times is the duty time. If
the clock duty time and the clock pause time are selected in a way that
their total sum cannot correspond to the duty time, the duty time is auto-
matically rounded up.
Example:
Clock duty time = 5 sec., Clock pause time = 3 sec., selected duty time =
11 sec.
→ The duty time is rounded up to 5+3+5 = 13 sec.
8 Maintenance / Service
IMPORTANT
Please observe the safety regulations in chapter 2 when servicing
the device.
If the timer is continually subjected to atmospheric influences the seal in the cover
and the electric lines should be regularly checked (at least every 6 months) for signs
of porosity.
All other parts are maintenance-free.
9 Troubleshooting
DANGER
ATTENTION:
Troubleshooting of AP 117 electronic timers should only be conducted
by an authorized specialist.
Fault
Possible causes
Troubleshooting
Remedy
Timer does
not start
Phase interruption
Check fuses and con-
nection cables
Replace fuse or
connection cable
Supply voltage too
low
Check supply voltage
and cables
Use correct supply
voltage
Cable wires have
been connected po-
larity-reversed
Check polarity
Connect cable
wires with correct
polarity
Timer fails
when operat-
ing in „RUN”
Voltage drop under
load
Check supply connec-
tion
Use correct supply
voltage