background image

15 

 

 

 

IMPORTANT

 

A cycle has to consist of at least two clock duty times and one clock pause 
time. 

 

 

IMPORTANT

 

The total sum of clock duty times and clock pause times is the duty time. If 
the clock duty time and the clock pause time are selected in a way that 
their total sum cannot correspond to the duty time, the duty time is auto-
matically rounded up. 
Example:  
Clock duty time = 5 sec., Clock pause time = 3 sec., selected duty time = 
11 sec. 

→ The duty time is rounded up to 5+3+5 = 13 sec. 

 

 
 
 

8  Maintenance / Service 

 

IMPORTANT

 

Please observe the safety regulations in chapter 2 when servicing 
the device. 

 
If the timer is continually subjected to atmospheric influences the seal in the cover 
and the electric lines should be regularly checked (at least every 6 months) for signs 
of porosity. 
All other parts are maintenance-free.

 
 

9  Troubleshooting 

 

DANGER

 

ATTENTION: 

Troubleshooting of AP 117 electronic timers should only be conducted 
by an authorized specialist. 

 

Fault

 

Possible causes

 

Troubleshooting

 

Remedy

 

Timer does 
not start 

Phase interruption 

Check fuses and con-
nection cables 

Replace fuse or 
connection cable 

Supply voltage too 
low 

Check supply voltage 
and cables 

Use correct supply 
voltage 

Cable wires have 
been connected po-
larity-reversed 

Check polarity 

Connect cable 
wires with correct 
polarity 

Timer fails 
when operat-
ing in „RUN” 

Voltage drop under 
load 

Check supply connec-
tion 

Use correct supply 
voltage 

 

Summary of Contents for AP 117

Page 1: ...Operating Instructions for October 2015 Netter Electronic Timer BA No 1651E Type AP 117 Page 1 16 These operating instructions apply to Type AP 117 ...

Page 2: ...11 ENCLOSURES 16 Scope of delivery The AP 117 are delivered with the follow ing components as standard Electronic Timer AP 117 Operating Instructions Packaging For changes to the scope of delivery please refer to the delivery note Check the packaging for possible signs of transport damage In the event of damage to the packaging check that the contents are complete and undamaged If there is any dam...

Page 3: ...tion is subject to copy right All rights e g for translation photo mechanical reproduction printing or reproduction e g data processing data carriers and data networks of this operating manual or parts thereof are strictly reserved to NetterVibration Limitation of liability All technical information data and in structions on installation operation and maintenance in these operating instructions ar...

Page 4: ...risk which if not avoided can result in serious injury IMPORTANT note with especially useful information and tips ENVIRONMENTALLY FRIENDLY DISPOSAL refers to the obligation of an environmentally friendly dis posal Information on the AP 117 Netter type AP 117 electronic timers comply with the directive for electromag netic compatibility 2014 30 EU and the low voltage directive 2014 35 EU Standards ...

Page 5: ...only be carried out by authorized qualified personnel Handling the electronic timer always lies in the responsibility of the opera tor CAUTION Netter GmbH does not assume liability for damage or injury result ing from technical modifications to the product or failure to ob serve the instructions and warnings in this operating manual DANGER Live parts can cause severe or even deadly injury DANGER D...

Page 6: ...VA in operation 0 25 VA standby Operating voltage AC 90 V to 240 V Switching current AC 1 25 A or Operating voltage DC 24 V 48 V 5 protected against reverse polarity Switching current DC 1 25 A Switching current DC at 24 V and max 40 C to 2 A Ambient temperature 20 C to 60 C The operating temperatures must not be ex ceeded or fallen short of Protection IP 65 RFI suppressed Cable diameter 4 5 mm to...

Page 7: ...7 Dimensions Cable gland ...

Page 8: ...ns Function standard Function cascade interval pulse mode Function standard The sequence begins with the duty time RUN which can be adjusted from 1 s to 99 h During this time the supply volt age is applied to the timer output When the duty time ends the pause time PAUSE of 1 s to 99 h runs then the duty time etc Function cascade interval pulse mode The sequence begins with the duty time which can ...

Page 9: ...ny damage inform the shipping agent The electronic timer is packed ready to install At delivery the fuse is located in the socket When transporting electronic timers it should be ensured that they are not subjected to severe impacts or vibra tions The units should be stored in a clean dry environment If electronic timers are in storage for longer periods the temperature in the store room must not ...

Page 10: ...tallation of the AP 117 electronic timer may only be per formed by authorized specialists The authorized specialists must work only with insulated tools which are suitable for the application CAUTION Only suitable and flexible supply cables should be used for the connec tion of the electronic timers AP 117 Cables and earthing conductors must be connected according to the respective regulations The...

Page 11: ...ia the power connection block 1 and 2 DC or AC terminal 3 PE AC The output voltage is applied to the terminals 4 and 5 AC or DC terminal 6 PE AC Direct voltage If direct voltage DC is applied to the terminals 1 and 2 direct voltage DC is also applied to the terminals 4 and 5 Alternating voltage If alternating voltage AC is applied to the terminals 1 and 2 alternating voltage AC is also applied to ...

Page 12: ... red LED flashes In the adjusting or operating mode the LED lights when active keys are touched DANGER AUTOMATIC START When switched on the AP 117 starts immediately with the stored time values The connected devices also start immediately IMPORTANT The sensor keys react to slight touching not to pressing DANGER DANGER AUTOMATIC START If following a voltage interruption power is again applied to th...

Page 13: ...d when the points have extinguished The outputs terminals 4 5 are en ergized while the duty time is run ning Adjusting the pause time If the timer is switched off the out puts terminals 4 5 are de energized Touch the key ON OFF until the displays are illuminated The electronic timer starts immediately with the stored time values Touch the key until two addi tional illuminated points appear in the ...

Page 14: ...g again the key for at least 3 seconds The values are stored when the points have extinguished The outputs terminals 4 5 are en ergized while the clock duty time is running Adjusting the clock pause time If the timer is switched off the out puts terminals 4 5 are de energized Touch the key ON OFF until the displays are illuminated The electronic timer starts immediately with the stored time values...

Page 15: ...is continually subjected to atmospheric influences the seal in the cover and the electric lines should be regularly checked at least every 6 months for signs of porosity All other parts are maintenance free 9 Troubleshooting DANGER ATTENTION Troubleshooting of AP 117 electronic timers should only be conducted by an authorized specialist Fault Possible causes Troubleshooting Remedy Timer does not s...

Page 16: ... Housing Cover ENVIRONMENTALLY FRIENDLY DISPOSAL All devices can be disposed of through Netter GmbH The applicable disposal prices are available upon request 11 Enclosures Enclosure s Declaration of Conformity IMPORTANT Additional information available upon request Leaflet No 35 etc ...

Reviews: