2 Safety
Designated use:
Electronic timers are used wherever a
procedure needs to be time-controlled.
AP 117 electronic timers are suitable
for timed activation of electric external
vibrators, solenoid valves and motor
overheating protection.
With these timers electric vibrators,
pneumatic vibrators, pneumatic im-
pactors and other drives can be
switched on and off exactly to the sec-
ond.
By selecting suitable pause times, the
operation of the vibrators is optimized,
drive energy can be saved and the
noise level lowered.
Any other usage is considered to be
improper.
The electronic timer has no safety de-
vices of its own.
Qualified Personnel:
Installation, start-up, maintenance and
fault correction of the electronic timer
may only be carried out by authorized,
qualified personnel.
Handling the electronic timer always
lies in the responsibility of the opera-
tor.
CAUTION
Netter GmbH does not assume liability for damage or injury result-
ing from technical modifications to the product or failure to ob-
serve the instructions and warnings in this operating manual.
DANGER
Live parts can cause severe or even deadly injury.
DANGER
DANGER
AUTOMAT-
IC START
If, following a voltage interruption, power is again applied to the power
supply connection, the next cycle will always begin with the set duty
time.
The output is immediately energized.
DISCON-
NECT
POWER
SUPPLY
When working on the electronic timers they must be isolated from the
mains supply. To do so please proceed as follows:
1. Switch off the electronic timer
2. Secure against switching on again
3. Make sure it is de-energized
4. Earth and short-circuit
5. Cover or isolate any neighboring voltage parts