DVR Server Manual
37
The interface here displays all the IP devices can be searched and
connected.
Check the box in front of Enable 3G to use the 3G function of DG series IP
cameras. For details, please refer to Appendix E.
Note:
Because the search tool is using multicast protocol and the firewall forbids
the multicast data packet, so please close the firewall first to make sure DG
series IP devices can be found.
Select one device from the list and click
button to add it to
the DVR system.
When you finished adding IP Camera to DVR system, it will show the
status of that camera, including Sever name, IP Address, connect port,
sequence number for IP Camera, connect status and register information.
Note:
After you add IP cameras to DVR system, they will be collocated
sequence numbers after local board cards. The sequence numbers of the IP
cameras change dynamically according to the total numbers of local board
cards and the sequences of the IP cameras that have been added to DVR
system. For example, if there are 32 channels local board cards, then you add
2 IP cameras. They will be collocated 33 and 34 as their sequence numbers.
Then if you add another board card (4 channels), the sequence numbers of
them will change to 37 and 38 dynamically.
(2).
Modify IP camera
Press
button to modify IP camera’s information, its interface is
same as Add IP Camera.
For the cameras connected via 3G, you can’t modify them. You have to
delete and then modify them before you add them to the DVR again.
(3).
Delete IP camera device
Press
button to delete a connected server. When system is in
the course of adding an IP camera device (“connecting…”indicated in connect
status column), user cannot delete that IP camera device.
(4).
Decode card work mode
DVR system supports playing video of IP Camera to TV wall directly, and
then it uses the hard decoding function of decoder, so you should set the work
mode of decoder. If you don’t use hard decoding, you can’t output video of IP
Camera real-time, user can only play back recording data to TV monitor by