8
Example#2
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e.
BatteryVoltageChange= 0.1V.
MaxTime
S
leeping(MinTime) sleeping sleeping sleeping
0H
15
th
M 30
th
M 45
th
M
1H
2H
Example#3
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=
0.1V.
MaxTime
sleeping sleeping
...
0H
15
th
M
30
th
M
45
th
M 1H
1H 10
th
M
1H 25
th
M
1H 40
th
M 1H 55
th
M
2H 10
th
M
Notes:
1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it
does not collect data.
2) The data collected is compared with the last data reported. If the data change value is greater than the
ReportableChange value, the device reports according to MinTime interval. If the data variation is not greater than
the last data reported, the device reports according to MaxTime interval.
3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device
wakes up frequently and the battery will be drained soon.
4) Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval,
another cycle of MinTime / MaxTime calculation is started.
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORTS
2.8V
Wakes up and collects
data
REPORT 2.8V
Wakes up and
collects data
REPORTS 2.8V
Wakes up and collects data
2.7V |2.7-2.8|=0.1
REPORTS 2.7V
Wakes up and
collects data
2.7V Does not
report
Wakes up and
collects data 2.7V
Does not report
Wakes up and
collects
data
2.7V Does not
report
Wakes up and collects data
2.7V Does not report
Wakes up and
collects data
2.8V Does not
report
Users push the button,
REPORTS 2.7V.
Recalculate MaxTime.