Example of ConfigureCmd 

 

FPort

0x07 

 

Bytes 

Var (Fix =9 Bytes) 

 

CmdID 

DeviceType 

NetvoxPayLoadData 

CmdID

– 1 byte 

DeviceType

– 1 byte – Device Type of Device 

NetvoxPayLoadData

– var bytes (Max=9bytes) 

 

 

 

(1)

 

  Command Configuration:

 

  MinTime = 1min

MaxTime = 1min

BatteryChange = 0.1v 

     Downlink

014D003C003C0100000000       003C(H

ex) 

= 60(D

ec) 

   

     Response

 

                814D000000000000000000

Configuration success

 

               814D010000000000000000

Configuration failure

 

 

(2)

 

  Read Configuration:

 

     

Downlink

024D000000000000000000 

     Response

 

               824D003C003C0100000000

Current configuration

 

 
 
 
 
 

Description 

Device 

Cmd 

ID 

Device 

Type 

NetvoxPayLoadData 

Config 

ReportReq 

R312A 

0x01 

0x4D 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

BatteryChange 

(1byte Unit:0.1v) 

Reserved 

(4Bytes,Fixed 0x00) 

Config 

ReportRsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes,Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfigR

eportRsp 

0x82 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

BatteryChange 

(1byte Unit:0.1v) 

Reserved 

(4Bytes,Fixed 0x00) 

Summary of Contents for R312A

Page 1: ...This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 10 7 Important Maintenance Instruction 11...

Page 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building aut...

Page 4: ...m Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility Thi...

Page 5: ...network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network...

Page 6: ...r Max Interval The device will immediately send a version packet report along with an uplink packet including alarm status The device sends data in the default configuration before any configuration i...

Page 7: ...0000000 Configuration failure 2 Read Configuration Downlink 024D000000000000000000 Response 824D003C003C0100000000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config...

Page 8: ...iguration Description CmdID PayLoad Fix byte 1byte SetButtonPressTimeReq 0x01 PressTime 1byte 0x00_QuickPush_Less then 1 Second 0x01_1 Second push 0x02_2 Seconds push 0x03_3 Seconds push 0x04_4 Second...

Page 9: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Page 10: ...ts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval val...

Page 11: ...neck with a lanyard Note Do not install the device in a metal shielded box or other electrical equipment around it to avoid affecting the wireless transmission of the device The emergency button R312...

Page 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: