5
5. Data Report
Data report configuration and sending period are as following:
Min. Interval
(Unit:second)
Max. Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min. Interval
Report
per Max. Interval
When the device is turned on, it will immediately send a version package and a report data.
Data will be reported once per hour by default setting.
Default Setting:
Maximum time: 0x0E10 (3600s)
Minimum time: 0x0E10 (3600s) // Detect the current voltage value every 3600s by default setting
Battery Change: 0x01 (0.1V)
R718MBC Vibration:
The device detects sudden movement or vibration to start timing, and ends the time after entering the stationary state
for 5 seconds, sends a report of the vibration duration, and restarts a new round of detection, and the timing is cleared.
If vibration continues to occur during this process, the 5 seconds timing restarts until it reaches a standstill.
Active Threshold:
Active threshold range is 0x0003-0x00FF (default is 0x0003, the most sensitive)
Active Threshold = Critical value ÷ 9.8 ÷ 0.0625
* The gravitational acceleration at standard atmospheric pressure is 9.8 m/s
2
* The scale factor of the threshold is 62.5 mg
R718MB DeviceType:
0x01_R718MBA
0x02_R718MBB
0x03_R718MBC
The default value is the programming value.
Note:
1.
The device report interval will be programmed based on the default firmware which may vary.
2.
The interval between two reports must be the minimum time.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://cmddoc.netvoxcloud.com/cmddoc