5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
When the device is powered on, it will immediately send a version package Report and the report data with the voltage.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Max Interval = 60 min = 3600s
BatteryChange = 0x01 (Unit: 0.1v)
Note:
(1) By default, it will detect the current voltage every Min Interval.
If there is special customization, the settings will be changed according to customer’s requirements.
(2) The device report interval will be programmed based on the default firmware which may vary.
(3) The interval between two reports must be the minimum time.
(4) Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
to resolve uplink data.