7
5.1 Example of ReportDataCmd
FPort
:
0x06
Bytes
1
1
1
Var(Fix=8 Bytes)
Version
DeviceType
ReportType
NetvoxPayLoadData
Version
– 1 byte –0x01
——
the Version of NetvoxLoRaWAN Application Command Version
DeviceType
– 1 byte – Device Type of Device
The devicetype is listed in Netvox LoRaWAN Application Devicetype doc
ReportType
– 1 byte –the presentation of the NetvoxPayLoadData
,
according the devicetype
NetvoxPayLoadData
– Fixed bytes (Fixed =8bytes)
Example of Uplink: 0131012401000000000000
1
st
byte (01): Version
2
nd
byte (31): DeviceType 0x31
-
R718T(R718TB)
3
rd
byte (01): ReportType
4
th
byte (24): Battery
-
3.6v , 24 H
ex
=36 D
ec
36*0.1v=3.6v
5
th
byte (01): Alarm
6
th
~ 11
th
byte (000000000000): Reserved
5.2 Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
Device
Device
Type
ReportType
NetvoxPayLoadData
R718TB
0x31
0x01
Battery
(1Byte, unit:0.1V)
Alarm(1Byte)
0:noalarm 1:alarm)
Reserved
(6Bytes,fixed 0x00)