8
Description Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R718TB
0x01
0x31
MinTime
(2bytes, Unit: s)
MaxTime
(2bytes, Unit: s)
BatteryChange
(1byte, Unit: 0.1v)
Reserved
(4Bytes, Fixed 0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes, Unit: s)
MaxTime
(2bytes, Unit: s)
BatteryChange
(1byte, Unit: 0.1v)
Reserved
(4Bytes, Fixed 0x00)
(1)Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1vFPort7
Downlink: 0131003C003C0100000000
003C(H
ex)
= 60(D
ec)
Device returns:
8131000000000000000000 (configuration successful)
8131010000000000000000 (configuration failed)
(2)Read device parameters
Downlink: 0231000000000000000000
Device returns:
8231003C003C0100000000 (current device parameters)
5.3 Example of ButtonPressTime
FPort
:
0x0D
Description
CmdID
PayLoad(Var bytes)
SetButtonPressTimeReq
0x01
PressTime(1byte)
0x00_QuickPush_Less then 1 Second,
Other Value present the presstime such as
0x01_1 Second push,
0x02_2 Seconds push,
0x03_3 Seconds push,
0x04_4 Seconds push,
0x05_5 Seconds push,
and so on
SetButtonPressTimeRsp
0x81
Status(0x00_Success