background image

 

 

Device

 

CmdID

 

Device 

Type

 

NetvoxPayLoadData

 

R718Y 

0xAC 

0x01 

Battery 

(1byte, Unit: 0.1v) 

DifferentPressure 

(Signed2Bytes, Unit: 0.1Pa) 

TemperatureChange   

(Signed2Bytes,Unit:0.1°C) 

Reserved 

(3Bytes, Fixed 0x00) 

 

Uplink: 

01AC0124001E0116000000 

1

st

 byte (01): Version   

2

nd

 byte(AC): DeviceType 0xAC 

  R718Y   

3

rd

 byte (01): ReportType   

4

th

 byte (24): Battery, 24 H

ex

=36 D

ec

    36*0.1v=3.6v   

5

th

 6

th

 byte (001E): Different Pressure, 1E H

ex

 =30 D

ec 

  30*0.1Pa=3 Pa 

7

th

 

8

th

 byte (0

11

6): Temperature Change, 116 H

ex

 =278 D

ec 

  278*0.1°C=27.8°C 

9

th

 ~11

th

 byte (000000): Reserved 

5.2 Example of ConfigureCmd 

FPort

0x07 

Bytes 

Var(Fix =9 Bytes) 

 

CmdID 

DeviceType 

NetvoxPayLoadData 

CmdID

– 1 byte 

DeviceType

– 1 byte – Device Type of Device 

NetvoxPayLoadData

– var bytes (Max=9bytes) 

Description  Device  CmdID 

Device 

Type 

NetvoxPayLoadData 

Config 

ReportReq 

R718Y 

0x01 

0xAC 

MinTime 

(2bytes, Unit: s) 

MaxTime 

(2bytes, Unit: s) 

BatteryChange 

(1byte, Unit: 0.1v) 

DifferentPressure 

Change 

(2bytes Unit:0.1Pa)   

TemperatureChange 

(2byte Unit:0.1°C)   

 

Config 

ReportRsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes, Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes, Unit: s) 

MaxTime 

(2bytes, Unit: s) 

BatteryChange 

(1byte, Unit: 0.1v) 

DifferentPressure 

Change   

(2bytes, Unit: 0.1Pa) 

TemperatureChange 

(2byte Unit:0.1

°C

(1)

 

Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, DifferentPressureChange=10Pa, 

TemperatureChange = 10℃

 

Downlink: 01AC003C003C0100640064     003C(H

ex) 

= 60(D

ec)

 

     Device returns: 

                  81AC000000000000000000 (configuration successful) 

Summary of Contents for R718Y

Page 1: ... proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice Wireless Differential Pressure and Temperature ...

Page 2: ... 5 5 Data Report 6 5 1 Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 7 5 3 Example for MinTime MaxTime logic 8 6 Information about Battery Passivation 9 6 1 To determine whether a battery requires activation 9 6 2 How to activate the battery 9 7 Important Maintenance Instruction 10 ...

Page 3: ...hods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti interference ability and so on LoRaWAN LoRa...

Page 4: ...configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Battery Life Please refer to web http www netvox com tw electric electric_calc html At this website users can find battery life time for variety models at differen...

Page 5: ... Never joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green indicator stays on for 5 seconds success The green indicator remains off fail Function Key Press and hold for 5 seconds Restore to factory setting Turn off The gr...

Page 6: ... in the default configuration before any configuration is done Default setting MaxTime Max Interval 15 min 900s MinTime Max Interval 15 min 900s BatteryChange 0x01 Unit 0 1v Different Pressure Change 0x0A 1 Pa Unit 0 1Pa Temperature Change 0x0A 1 C Unit 0 1 Measurement Range Different pressure Measuring Range 500 to 500 Pa Temperature Measuring Range 20 to 50 Pressure Difference And Temperature De...

Page 7: ... byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes Description Device CmdID Device Type NetvoxPayLoadData Config ReportReq R718Y 0x01 0xAC MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v DifferentPressure Change 2bytes Unit 0 1Pa TemperatureChange 2byte Unit 0 1 C Config ReportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x0...

Page 8: ...tageChange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data REPORTS 3 6V Wakes up and collects data REPORT 3 6V Wakes up and collects data REPORTS 3 6V Wakes up and colle...

Page 9: ...ergy density However primary lithium batteries like Li SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high This lithium chloride layer prevents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may also...

Page 10: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...

Reviews: