4
4.
Set up Instruction
On/Off
Power on
Insert batteries. (Users may need a screwdriver to open)
Turn on
The magnet approach to the top cover for 3 seconds.
Note:
The device is in the geomagnetic initialization state within 3 minutes after turning on. Please do
not move the device or cause changes in the surrounding magnetic field.
Turn off
(Restore to factory setting)
The magnet approach to the top cover for 10 seconds
Power off
Remove Batteries.
Note:
1.
The device will be off after removing the battery and insert it again.
2.
It is suggested to wait for at least 10 seconds between turning the device on and off.
3.
To enter the engineering test mode: At 1
st
to 5
th
second after power on
Network Joining
Never joined the network
Turn on the device, and it will search for the network to join.
Had joined the network
(not at factory setting)
Turn on the device, and it will search for the previous network to join.
Reed Switch Function
The magnet close to the top cover
for 10 seconds
Restore to factory setting / Turn off
The magnet close to the top cover
shortly
The device is in the network: sends a report
Sleeping Mode
The device is on and in the network
Sleeping period: Min Interval.
When the reportchange exceeds setting value: send a data report according to Min Interval.
Note:
Suggest to remove batteries if the device is not used.
Suggest to check device verification on gateway.
Low Battery Threshold
Low Voltage
3.2 V
* Could use the magnet of R311A as the magnet mentioned in the article. For specific operation, please refer to the installation