8
Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
ConfigReport
Req
R720F
0x01
0xB7
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed 0x00)
ConfigReport
Rsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
Reserved
(4Bytes,Fixed 0x00)
(
1
)
Configure R720F device parameter MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
Downlink: 01B7003C003C0100000000
Device return
:
81B7000000000000000000 (configuration success)
81B7010000000000000000 (configuration failure)
(
2
)
Read R720F device parameter
Downlink: 02B7000000000000000000
Device return
:
82B7003C003C0100000000 (device current parameter)