7
Report Configuration
(
1
)
Configure RA0715 device parameter MinTime = 30s, MaxTime = 900s
Downlink: 0105001E03840000000000
Device Return:
8105000000000000000000 (configuration success)
8105010000000000000000 (configuration failure)
*Note:
The value of MinTime should be
≥
30s (US915, AU915, KR920, AS923, IN865)
The value of MinTime should be
≥
120s (EU868)
The value of MaxTime should be
≥
900s
(
2
)
Read RA0715 device parameter
Downlink: 0205000000000000000000
Device Return:
8205001E03840000000000 (device current parameter)
Description
Device
CmdI
D
DeviceType
NetvoxPayLoadData
ConfigRepo
rtReq
RA0715
R72615
RA0715Y
0x01
0x05
0x09
0x0D
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit: s)
Reserved
(5Bytes, Fixed 0x00)
ConfigRepo
rtRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes, Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
Reserved
(5Bytes, Fixed 0x00)