background image

                                                                                                               

    Model

R809A01     

 

 

 

 

Wireless  Plug-and-Play  Power  Outlet  with  Consumption  Monitoring  and  Power  Outage 

Detection 

 

 

 

 

 

 

 

 

 

Wireless Plug-and-Play Power Outlet   

with Consumption Monitoring and   

Power Outage Detection 

 

R809A01 

User Manual 

 

 

 

 

 

 

 

 

 

 

Copyright© Netvox Technology Co., Ltd.

 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained 

in  strict  confidence  and  shall  not  be  disclosed  to  other  parties,  in  whole  or  in  part, without  written  permission  of  NETVOX 

Technology. The specifications are subject to change without prior notice. 

 

Summary of Contents for R809A01

Page 1: ...e Detection R809A01 User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Characteristic 3 4 Operation 4 5 Data Report 5 6 Load Property 9 7 Product Installation 10 8 Important Maintenance Instruction 11...

Page 3: ...type R809A01I AU type LoRa Wireless Technology LoRa is a wireless communication technology famous for its long distance transmission and low power consumption Compared with other communication methods...

Page 4: ...ion parameters can be configured through a third party software platform Available third party platform Actility ThingPark TTN MyDevices Cayenne Current voltage power and energy detection Over current...

Page 5: ...mation on the gateway or consult your platform server provider Function Key Restore to factory setting Press and hold the factory restoring key for 5 seconds to restore to factory setting The green in...

Page 6: ...s data in the default configuration before any configuration is done Default setting MaxTime Max Interval 900s 15 min MinTime Min Interval 2 s Current Change 0x0064 100mA Power Change 0x14 20W Note 1...

Page 7: ...alarm 1 alarm DashCurrentAlarm 1Byte 0 noalarm 1 alarm PowerOffAlarm 1Bytes 0 noalarm 1 alarm 0x02 Vol 2Bytes Unit 1V Current 2Bytes Unit 1ma Power 2Bytes Unit 1W Reserved 2Bytes fixed 0x00 Uplink exa...

Page 8: ...eportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2b...

Page 9: ...If the data change is not greater than the last reported data the device will report based on the MaxTime interval 2 For the energy consumption detection device because the device is a constant power...

Page 10: ...6 Load Property When the detected current exceeds the rated load current range the device will automatically disconnect the load within 2 seconds after the detection Rated Load AC Max Load Max Induct...

Page 11: ...imited to the following Family School Hospital Shopping mall When electrical equipment needs turn on off regularly remote and scene control The Wireless Power Outlet R809A01 is a removable plug and pl...

Page 12: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...

Reviews: