Example of ConfigureCmd 

 

FPort

0x07 

 

Bytes 

Var(Fix =9 Bytes) 

 

CmdID 

DeviceType 

NetvoxPayLoadData 

CmdID

– 1 bytes   

DeviceType

– 1 byte – Device Type of Device 

NetvoxPayLoadData

– var bytes (Max=9bytes) 

 

Description 

Device 

CmdID 

DeviceType 

NetvoxPayLoadData 

Off 

R809A01 

0x90 

0x0E 

Reserved 

(9Bytes,Fixed 0x00) 

On 

0x91 

Reserved 

(9Bytes,Fixed 0x00) 

Toggle 

0x92 

Reserved 

(9Bytes,Fixed 0x00) 

ClearEnergy 

0x93 

Reserved 

(9Bytes,Fixed 0x00) 

ReadCurrentStatus 

0x94 

Reserved 

(9Bytes,Fixed 0x00) 

Config 

ReportReq 

0x01 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

CurrentChange 

(2byte 

Unit:1mA) 

PowerChange

2byte 

Unit:1W

 

Reserved 

(1Byte,Fixed 

0x00) 

Config 

ReportRsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes,Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

CurrentChange 

(2byte 

Unit:1mA) 

PowerChange

2byte 

Unit:1W

 

Reserved 

(1Byte,Fixed 

0x00) 

(1)

 

Turn off the R809A01 switch button   

    

Downlink: 900E000000000000000000   

(2)

 

Turn on the R809A01 switch button 

     

Downlink: 910E000000000000000000   

(3)

 

Toggle turn on/off switch button 

     

Downlink: 920E000000000000000000   

(4)

 

Clear the historical electrical energy data 

     

Downlink:930E000000000000000000   

(5)

 

Setting Min Interval = 2 seconds, 

Max Interval

 = 300 seconds,

 

Current Change = 100mA,Power Change = 20W 

  Downlink:

010E0002012C0064001400

 

Response: 810E000000000000000000    (successful) 

(6)

 

Read the current report interval   

Downlink: 

020E000000000000000000

   

Response:

820E0002012C0064001400

 

 

Summary of Contents for R809A01

Page 1: ...e Detection R809A01 User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Characteristic 3 4 Operation 4 5 Data Report 5 6 Load Property 9 7 Product Installation 10 8 Important Maintenance Instruction 11...

Page 3: ...type R809A01I AU type LoRa Wireless Technology LoRa is a wireless communication technology famous for its long distance transmission and low power consumption Compared with other communication methods...

Page 4: ...ion parameters can be configured through a third party software platform Available third party platform Actility ThingPark TTN MyDevices Cayenne Current voltage power and energy detection Over current...

Page 5: ...mation on the gateway or consult your platform server provider Function Key Restore to factory setting Press and hold the factory restoring key for 5 seconds to restore to factory setting The green in...

Page 6: ...s data in the default configuration before any configuration is done Default setting MaxTime Max Interval 900s 15 min MinTime Min Interval 2 s Current Change 0x0064 100mA Power Change 0x14 20W Note 1...

Page 7: ...alarm 1 alarm DashCurrentAlarm 1Byte 0 noalarm 1 alarm PowerOffAlarm 1Bytes 0 noalarm 1 alarm 0x02 Vol 2Bytes Unit 1V Current 2Bytes Unit 1ma Power 2Bytes Unit 1W Reserved 2Bytes fixed 0x00 Uplink exa...

Page 8: ...eportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2b...

Page 9: ...If the data change is not greater than the last reported data the device will report based on the MaxTime interval 2 For the energy consumption detection device because the device is a constant power...

Page 10: ...6 Load Property When the detected current exceeds the rated load current range the device will automatically disconnect the load within 2 seconds after the detection Rated Load AC Max Load Max Induct...

Page 11: ...imited to the following Family School Hospital Shopping mall When electrical equipment needs turn on off regularly remote and scene control The Wireless Power Outlet R809A01 is a removable plug and pl...

Page 12: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...

Reviews: