background image

                                                                                                                         

Model

R831D   

 

 

 

 

Wireless Relay Switch Control 

 

 

 

 

 
 
 

Wireless Relay Switch Control

 

 

 

 

R831D 

 

User Manual 

 

 

 

 

 

 

 

 

 

 

Copyright© Netvox Technology Co., Ltd.

 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict 

confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The 

specifications are subject to change without prior notice. 

 

Summary of Contents for R831D

Page 1: ... Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ...1 Table of contents 1 Introduction 2 2 Appearance 3 3 Main Features 4 4 Set up Instruction 5 5 Data Report 6 6 Installation 10 7 Maintenance and maintenance 11 ...

Page 3: ...logy famous for its long distance transmission and low power consumption Compared with other communication methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless security systems indust...

Page 4: ...Port 4 Second load Port 5 Second load Port 6 Third load Port 7 Third load Port 8 GND Port 9 12v R831D DIP SW 1 2 3 on off 1 3 DIP Switch Change R831 series mode V N A G GND K1 input 1 K2 input 2 K3 input 3 Network Indicator Status Indicator DIP Switch Function Key ...

Page 5: ...can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Battery Life Please refer to web http www netvox com tw electric electric_calc html At this website users can find battery life time for variety models at different configurations 1 Actual range may vary depending on environment 2...

Page 6: ...he network successfully The network indicator stays off Fail to join the network If the device has joined the network and it is not set to default Turn on the device and it will search for the previous network to join The network indicator stays on Joins the network successfully The network indicator stays off Fail to join the network Function Key Press the function key and hold the pressing for 5...

Page 7: ... immediately send a version packet report along with an uplink packet including 3 relay status and 3 input status The device sends data in the default configuration before any configuration is done Default setting MaxTime Max Interval 900s MinTime Min Interval 2s Note The device report interval will be programmed based on the default firmware which may vary The interval between two reports must be...

Page 8: ...ytes Fixed 0x00 ReadConfigReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfigReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Reserved 5Bytes Fixed 0x00 SetSwitchTypeReq 0x03 SwitchType 1byte 0x00_Toggle 0x01_Momentary Reserved 8Bytes Fixed 0x00 SetSwitchTypeRsp 0x83 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetSwitchTypeReq 0x04 Reserved 9Bytes Fixed 0x00 GetSwitchTypeRsp 0x84 Swi...

Page 9: ...mal close connect Downlink 91B0070000000000000000 bit0 relay1 bit1 relay2 bit2 relay3 5 Toggle relay normal open close Downlink 92B0070000000000000000 bit0 relay1 bit1 relay2 bit2 relay3 Relay switch Type Change relay switch type a Toggle Normal open close type switch ex toggle switch b Momentary Tact type switch ex tact switch 6 Setting switch type is tact type switch Downlink 03B0010000000000000...

Page 10: ...ur MaxTime MinTime MinTime MinTime MinTime MinTime MinTime 0H 15th M 30th M 45th M 1H 1H15th M 1H30th M Note The status has changed it will be reported at MinTime and recommend the MinTime Interval set as 2 seconds Collects data ON REPORT ON Collects data OFF Does not report Collects data REPORTS OFF Collects data REPORTS ON Collects data REPORTS ON Collects data REPORTS OFF Collects data REPORTS ...

Page 11: ...SW 1 6 Installation This product does not have a waterproof function After joined the network please place it indoors The wiring diagram as follow below SW 3 SW 2 Adapter First Load Second Load Third Load ...

Page 12: ...t some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do not a...

Reviews: