How to use
When the device has successfully joined to the network and has enrolled to a CIE device,
the device is ready to be used.
When Z801TXB detects signal from the sensor head or heads, it will trigger an event
reporting message to the CIE device for a corresponding alarm to notify the user.
Overcoming a sleeping device
The Z801TXB is a battery powered device and is designed to quickly enter sleep mode
when idle to save power. Sometimes during system setup you would want to retrieve
information (i.e. IEEE address, short address) from the device so you need to press key to
allow the device to enter wake mode to stay connected.
Operation:
Hold press binding key for 3 seconds
status indicator flashes once
and
network
indicator flashes 5 times
. The device should automatically announce information to the
air. The device would stay awake for a while but short.
Restore to factory setting
Z801TXB is capable of storing and saving includes network routing information. If you
wish to remove Z801TXB from the network, you would need to clear it to join to a new
network by simply reset the device to restore to the factory setting.
Operation:
1. Remove the power then hold on to the binding key.
Note: make sure that the power is fully drained: leave the power out for 30 seconds or
press the binding key twice for fast power release.
2. Press and hold the binding key and then give power to Z801TXB. Release the key. You
will see the status LED flashes quickly indicating restore to factory setting is successful.
Now if you wish Z801TXB to join to a new network please power cycle the device again to
put the device into search for a network mode (refer to
network association
in this
manual).