Battery disposal
This device uses AAA size battery. When the battery is bellowing 2.4V DC, the device will
not work and the status indicator will steadily flash to notify the user to replace it.
Warning: Do not cast battery into the fire. The battery may be explosive and may cause
injuries.
Installation
Sensor connection
Connect the sensor cable into the signal input ports. One sensor to one signal port
configuration. Also connect the sensor’s negative cable to the common ground port.
Since Z801TXB can be triggered by signal change, Z801TXB sensor selection must be
those that give either open or close circuit configuration.
You may program the device so that it may trigger either by an open or a close state of the
sensor at the time of device factory default.
Operation:
To program Z801TXB to trigger the alarm by
a close circuit sensor type
:
1. Restored the device to factory default setting. (Refer to restore device to factory
setting section in this manual)
2. Select a preferred S port and leave it as
an open circuit
.
3. Then power cycle the device.
The device regards
open circuit
as a normal status and therefore will not trigger the
alarm.
To program Z801TXB to trigger the alarm by
an open circuit sensor type
:
1. Restored the device to factory default setting. (Refer to restore device to factory
setting section in this manual)
2. Select a preferred S port and connect the sensor in such a way that it is
a close
circuit
.
3. Then power cycle the device.
The device regards
a short circuit
as a normal status and therefore will not trigger the
alarm.