background image

ZigBee

TM

- Measurement and Switch Socket

User Manual

Measurement and Switch Socket

Model: Z809A

Firmware: V3.5

Hardware: V1.2

Summary of Contents for Z809A

Page 1: ...ZigBeeTM Measurement and Switch Socket User Manual Measurement and Switch Socket Model Z809A Firmware V3 5 Hardware V1 2...

Page 2: ...ee Network 4 5 2 Permit Join 4 5 3 Binding 4 5 4 Control 5 5 5 Reset Power Consumption Summation 5 5 6 Restore to Factory Setting 5 5 7 Power Metering 5 5 8 Report Configuration for Developer Only 6 6...

Page 3: ...e ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is de...

Page 4: ...16 channels Power supply 100 240VAC 50 60Hz Power consumption 15mA 220V Resistive load 250VAC 16A Inductive load 220VAC 8A Monitoring range 100mA to 16A with 1 accuracy Relay lifetime 100 000 times Up...

Page 5: ...tor will stay green 5 2 Permit Join Z809A is designed to work as a router To allow other devices to join the ZigBee network users could enable the Permit Join feature using the tips A Press the Bindin...

Page 6: ...n once 5 6 Restore to Factory Setting To restore it to factory setting please follow the steps Step1 Press and hold the Binding Key for 15 seconds The network indicator will flash green 3 times at the...

Page 7: ...ltage if the device report has been previously configured it will issue 1 or 2 reports within 1 60 seconds randomly on the device and thereafter it will report according to the configuration Report se...

Page 8: ...h behaves This table lists the clusters which are supported by Z809A 1 End Point s 0x01 2 Device ID Mains Power Outlet 0009 3 EndPoint Cluster ID Attributes of the Basic Device Information attribute s...

Page 9: ...ter string 0 32 Bytes Read only netvox O 0x0005 ModelIdentifier Character string 0 32bytes Read only Z 809AE3 R O 0x0006 DateCode Character string 0 16 bytes Read only 20141020 O 0x0007 PowerSource 8...

Page 10: ...9 2 Select Mains Power Outlet to enter setting interface Click bind device as below 3 Click Power Status as below...

Page 11: ...d Load AC Remark Max Load with LEDs Remark Max Inductive Load cos 0 4 Max Load with Electric Motors Overload Protection with Auto Power Cutoff EU Type 16A 250V UK Type 13A 250V AU Type 10A 250V US Typ...

Page 12: ...spills to a device please leave the device dry properly before storing or using Do not use or store the device in dusty or dirty areas Do not use or store the device in extremely hot temperatures Hig...

Page 13: ...nce with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does caus...