A. There is no CIE device or no compatible CIE device in the network → the indicator flashes

red twice

.

B. There is a compatible CIE device in the network, but it is failed to enroll → the indicator flashes

red 4

times

. Users can press and hold the

Test Key

for 3 seconds to initiate the registration.

C. The enrollment is completed → the indicator flashes

red 6 times

.

NOTE:

Users had better NOT enroll multiple Zone devices at the same time to prevent registration failure.

5-3. Alert Test

To test the alert feature of ZA02A, press shortly

Test Key

once.

1. After ZA02A joining network and enrolled successfully, the buzzer rings for 5 seconds (3-5 times).
2. If this is the first alert test, the buzzer rings “jew jew” gradually for 5 times and dual color indicator flashes

alternately for 5 times. In the mean time, it will send alert to CIE devices.

3. During alert testing, if ZA02A receives fire alarm from CIE devices, it will send notification to the CIE

device and generates alert sound. The indicator keeps flashing.

4. If ZA02A is in the network but not enrolled → the buzzer rings for 5 seconds (3-5 times) and dual color

indicator flashes alternately for 5 times. In the mean time, it sends the enrollment request. After the
enrollment is successful, it will generate an alert sound when it is enrolled successfully. No action after the
device is fail to enroll.

5. If ZA02A is not in a network → it generates alert sound for 5 seconds (3-5 times). The dual color indicator

flashes alternately 5 times. Press shortly

Test Key

within 5 seconds during the buzzer rings to close alarm.

5-4. Air Pollution Sensing

When the air quality goes below a specified level, ZA02A would generate the sound to alert users. It will also
send the notification to CIE device or to the device which is bound using Cluster ID (0x0500). In the mean
time, the buzzer will ring and dual color indicator flashes alternately. Users can press shortly

Test Key

at this

moment to close buzzer and indicator. Or wait till air quality turns back to normal; the buzzer and indicator
will shut off automatically.

5-5. Announce and Restart

Press and hold the

Test Key

for 3 seconds to announce and green indicator will flash for 5 times.

Press and hold the

Test Key

for 10 seconds to restart ZA02A and green indicator will flash.

5-6. Low Voltage alert and Temperature Sensor

(1) Device uses 2 AAA 1.5V batteries. While battery power is lower than 2.4V, device will stop working.

When the sensor is triggered or

Test Key

is pressed, device will check low voltage status as well as every

hour. While detecting low voltage status, the device will send alert to CIE devices and buzzer rings for 1
Second (1-2 times). Dual color indicator flashes once alternately to remind users.

(2) 10 seconds after device is powered on, it will detect temperature every 30 seconds. Once the temperature is

Summary of Contents for ZA02A

Page 1: ...ZA02A Wireless Smoke Detector Photoelectric ZA02A Wireless Smoke Detector Photoelectric Firmware V3 1 Hardware V4 1 20150430...

Page 2: ...A02A 4 5 1 Join the ZigBee Network 4 5 2 Enroll in the ZigBee Security System 4 5 3 Alert Test 5 5 4 Air Pollution Sensing 5 5 5 Announce and Restart 5 5 6 Low Voltage alert and Temperature Sensor 5 5...

Page 3: ...urity unit CIE Control and Indicating Equipment device to send commands to a siren device to trigger an alarm What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 1...

Page 4: ...3 2 Product Appearance Binding Key Test Key L N Indicator Sensor Mounting...

Page 5: ...please refer to the user manual of the coordinator or the router to enable the permit join feature 2 Load batteries on ZA02A It will start to search and join the network 3 The green indicator will fl...

Page 6: ...ion after the device is fail to enroll 5 If ZA02A is not in a network it generates alert sound for 5 seconds 3 5 times The dual color indicator flashes alternately 5 times Press shortly Test Key withi...

Page 7: ...o join device into a new network it needs to be restored To restore it to factory setting please follow the steps Step1 Press and hold both Binding Key Test Key for 5 seconds till green indicator flas...

Page 8: ...entify 0x0003 Commission 0x0015 Poll Control 0x0020 IAS Zone 0x0500 Diagnostics Information 0x0B05 This lists the attributes of the basic information Identifier Name Type Range Access Default Mandator...

Page 9: ...0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x03 M 0x0010 LocationDescription Character string 0 17 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x...

Page 10: ...ures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the devic...

Reviews: