5
A. There is no CIE device or no compatible CIE device in the network → the indicator flashes
red twice
.
B. There is a compatible CIE device in the network, but it is failed to enroll → the indicator flashes
red 4
times
. Users can press and hold the
Test Key
for 3 seconds to initiate the registration.
C. The enrollment is completed → the indicator flashes
red 6 times
.
NOTE:
Users had better NOT enroll multiple Zone devices at the same time to prevent registration failure.
5-3. Alert Test
To test the alert feature of ZA02A, press shortly
Test Key
once.
1. After ZA02A joining network and enrolled successfully, the buzzer rings for 5 seconds (3-5 times).
2. If this is the first alert test, the buzzer rings “jew jew” gradually for 5 times and dual color indicator flashes
alternately for 5 times. In the mean time, it will send alert to CIE devices.
3. During alert testing, if ZA02A receives fire alarm from CIE devices, it will send notification to the CIE
device and generates alert sound. The indicator keeps flashing.
4. If ZA02A is in the network but not enrolled → the buzzer rings for 5 seconds (3-5 times) and dual color
indicator flashes alternately for 5 times. In the mean time, it sends the enrollment request. After the
enrollment is successful, it will generate an alert sound when it is enrolled successfully. No action after the
device is fail to enroll.
5. If ZA02A is not in a network → it generates alert sound for 5 seconds (3-5 times). The dual color indicator
flashes alternately 5 times. Press shortly
Test Key
within 5 seconds during the buzzer rings to close alarm.
5-4. Air Pollution Sensing
When the air quality goes below a specified level, ZA02A would generate the sound to alert users. It will also
send the notification to CIE device or to the device which is bound using Cluster ID (0x0500). In the mean
time, the buzzer will ring and dual color indicator flashes alternately. Users can press shortly
Test Key
at this
moment to close buzzer and indicator. Or wait till air quality turns back to normal; the buzzer and indicator
will shut off automatically.
5-5. Announce and Restart
Press and hold the
Test Key
for 3 seconds to announce and green indicator will flash for 5 times.
Press and hold the
Test Key
for 10 seconds to restart ZA02A and green indicator will flash.
5-6. Low Voltage alert and Temperature Sensor
(1) Device uses 2 AAA 1.5V batteries. While battery power is lower than 2.4V, device will stop working.
When the sensor is triggered or
Test Key
is pressed, device will check low voltage status as well as every
hour. While detecting low voltage status, the device will send alert to CIE devices and buzzer rings for 1
Second (1-2 times). Dual color indicator flashes once alternately to remind users.
(2) 10 seconds after device is powered on, it will detect temperature every 30 seconds. Once the temperature is