6
2)
、
IRDetectionTime: 0
Once ZB11D turns to “occupied”, IR detection closes for IR delay*70%. ZB11D starts to detect from IR
delay*70% to full IR delay. If it detects events in this time, IR delay will extend again till there is no more IR
event . “
Occupied
” status will turn to “
Unoccpied
”. ZB11D will report to bind device the status according to
report setting.
Note:
1.During the time of “PIRUnoccupiedToOccupiedDelay”, PIR detects once per second, make sure
PIRUnoccupiedToOccupiedDelay
>=
PIRUnoccupiedToOccupiedThreshold.
2. Once
IRDetectionTime
<
PIROccupiedToUnoccupiedDelay
,
it will automatically default to
IRDetectionTime
=
PIROccupiedToUnoccupiedDelay
3.
PIROccupiedToUnoccupiedDelay
must >= 5 seconds.
4. (APP control interface) Infrared detection means “IRDetectionTime” > = “IRDisableTime”.
(APP control interface) IR delay means “PIROccupiedToUnoccupiedDelay” must >= 5 seconds.
5-4. Infrared Sensor Report
This device supports “Voltage status” and “Occupancy status” report.
For “Voltage status” report:
(1) If ZB11D does not bind any device (
ClusterId: 0001
), it will not send report.
(2) After binding, ZB11D will send voltage status to bind device.
Default configuration:
Min: 3600s, Max: 3600s, Report change:1
For “Occupancy status” report:
(1) If ZB11D does not bind any device (
ClusterId: 0406
), it will not send report.
(2) After binding, ZB11D will send voltage status to bind device.
Default configuration:
Min: 0s, Max: 3600s, Report change:0
Note: it is recommended to set MinInterval as small as possible such like “0” for immediately detection and
avoid missing IR detection report.
5-5. Wake up ZB11D
When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake
up the device as the following steps:
Step1. Press the
Auxiliary Key
.
Step2. The indicator flashes
green 5 times
when ZB11D is online.
Step3. ZB11D will broadcast the device data to the ZigBee network.
ZB11D would be in active status for 2 minutes for communication.
Summary of Contents for ZB11D
Page 13: ...12 8 Installation 1 Indoor use only please check the installation places ...
Page 14: ...13 2 Detection coverage ...
Page 16: ...15 ...
Page 19: ...18 ...