7. Loading property

Rated Load

AC

**

Remark**

Max. Load

with LEDs

**Remark**

Max. Inductive

Load

cosφ=0.4

Max. Load

with Electric

Motors

Max. Surge

Endurable

Surge

Detecion

Overload

Protection

with Auto

Power Cutoff

10A/250V

400W/8

LEDs

for each gang

8A/250V

1.5HP/250V

150A

YES

Yes

This device is not waterproof, after network configuration, place it indoor.

Note

1. When measured current is over 10A, the device will cut power within 2 seconds and check if attribute
Bit1(Current OverLoad) level of ACAlarmsMask is 1. If it’s 1 and then device will send Alarm. If it’s 0 and then
device will not send Alarm. When alarm is on, AlarmCluster = 0x0B04, AlarmCode = 0xF0

network indicator

flash 10 times (10, 250, 250).

2. Power data saving chip AT2401 : saving data every 30 seconds.

Power data saving chip AT2402 : saving data every 10 seconds.
Power data saving chip:AT2404/08: saving data every second.

3. When device is loaded, it would generate peak power (150A) and device would cut off power in 3 seconds. It
will also send alarm warning, AlarmCluster = 0x0B04

AlarmCode = 0xEF

network indicator lashes 20 times

(20,250,250).

Summary of Contents for ZigBee Z825J

Page 1: ...ZigBeeTM Mains Power Outlet Scene Selector User Manual Mains Power Outlet Scene Selector Model Z825J Firmware V1 1 Hardware V1 0 and above 20150922...

Page 2: ...5 5 Setting up Z825J 5 5 1 Join the ZigBee Network 5 5 2 Permit Join 5 5 3 Binding 6 5 4 Control 6 5 5 Power Metering 7 5 6 Reset Power Consumption Summation 7 5 7 Restore to Factory Setting 7 6 Home...

Page 3: ...for ZigBee HA Profile network What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point po...

Page 4: ...Off Button 3 Indicator 3 Network Indicator Binding Key N In L In On Off Button 2 Indicator 2 On Off Button 1 Indicator 1 Scene Button 3 Indicator 3 Scene Button 2 Indicator 2 Scene Button 1 Indicator...

Page 5: ...outer whose permit join feature is enabled Z825J will be permitted to join the network Step1 Enable the permit join function valid for 60 seconds of a coordinator or a router please refer to the user...

Page 6: ...Selector i Store Scene After Z825J join a network users can add the device like ZC06 into a group scene using the following steps Step1 Identify the device which you would like to add Step2 Press and...

Page 7: ...ID 0x0508 Voltage Attribute ID 0x0505 Power Attribute ID 0x050B Power Factor Attribute ID 0x0510 The command to reset power consumption summation 0xE0 The format is Bits 8 16 8 8 8 Frame control Manuf...

Page 8: ...or will flash cyan 4 times at 3rd 6th 10th and the 15th second Step2 After releasing the Binding Key press any switch key Button 1 Button 2 Button 3 within 2 seconds The Network Indicator will be flas...

Page 9: ...ify 0x0003 Scene 0x0005 On Off 0x0006 Meter 0x0702 Only EP1 Diagnostics 0x0B05 Commissing 0x0015 Electrical Measurement 0x0B04 Only EP1 EndPoint 0x04 0x06 Cluster ID Cluster ID for Z825J Server side C...

Page 10: ...0003 HWVersion 8 bit Unsigned integer 0x00 0xff Read only 0x0A O 0x0004 ManufacturerName Character string 0 32 Bytes Read only netvox O 0x0005 ModelIdentifier Character string 0 32bytes Read only Z825...

Page 11: ...if attribute Bit1 Current OverLoad level of ACAlarmsMask is 1 If it s 1 and then device will send Alarm If it s 0 and then device will not send Alarm When alarm is on AlarmCluster 0x0B04 AlarmCode 0x...

Page 12: ...ures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the devic...

Reviews: