7
The indicator colors for 4 modes are
blue
→
red
→
cyan
→
pink
in sequence.
5-5. Power Metering
Z825J reports the power consumption data to the ZigBee network.
The related Cluster ID:
Simple Metering Cluster ID (0x0702)
Electrical Measurement Cluster ID (0x0B04)
The related Attribute ID of Simple Metering Cluster ID:
Current Attribute ID: 0xE000; unit: mA
Voltage Attribute ID: 0xE001; unit: V
Power Attribute ID: 0xE002; unit: kW
Energy Attribute ID: 0xE003; related to AttributeID CurrentSummationDeliver (0x0000); unit: kWh
The related Attribute ID of Electrical Measurement Cluster ID:
Current Attribute ID: 0x0508
Voltage Attribute ID: 0x0505
Power Attribute ID: 0x050B
Power Factor Attribute ID: 0x0510
The command to reset power consumption summation: 0xE0. The format is:
Bits:8
16
8
8
8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifer
Frame payload
Action
0x05
0x109F
0xe0
0x00
(clusterid
:
0x0702
,
Action
:
0x00)
5-6. Reset Power Consumption Summation
To reset the power consumption data, please follow the steps:
Step1. Press and hold the Binding Key for 20 seconds. The Network Indicator will flash
cyan 5 times
(at
3
rd
,6
th
, 10
th
, 15
th
, and the 20
th
second).
Step2. After releasing the Binding Key, press any switch key (Button 1/ Button 2/ Button 3) within 2
seconds. The Network Indicator will flash
cyan
once
.
5-7. Restore to Factory Setting
To restore Z825J to factory setting: