1. Introduction

Netvox ZA01B, a gas detector with heat sensor, acts as a Router Device in ZigBee network. ZA01B is featured to
play a role of the sensor (Zone device) in the ZigBee security system. When the leak is occurring, ZA01B would
send out the alert message to the Warning Device. ZA01B will also notify the central security unit, CIE (Control
and Indicating Equipment) device, to send commands to a siren device to trigger an alarm.

What is ZigBee?

ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple
network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a
general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for
industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation
and home automation, etc.

Summary of Contents for ZigBee ZA01B

Page 1: ...ZigBeeTM Wireless Methane Gas Detector User Manual Wireless Methane Gas Detector Model ZA01B 20151127...

Page 2: ...ZA01B 5 4 1 Join the ZigBee Network 5 4 2 Enroll in the ZigBee Security System 5 4 3 Permit Join 5 4 4 Alert Test 5 4 5 Gas Sensing 6 4 6 Announce 6 4 7 Reboot 6 4 8 Restore to Factory Setting 6 5 Ho...

Page 3: ...ndicating Equipment device to send commands to a siren device to trigger an alarm What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports mu...

Page 4: ...3 2 Product Appearance Binding Key Test Key L N Indicator Sensor Mounting...

Page 5: ...ISM band up to 16 channels Power supply 100 240VAC 50 60Hz Power consumption 19 8mA 220VAC Up to 195 meters wireless transmission range in non obstacle space Easy installation and configuration This...

Page 6: ...the security system The enrollment has these 3 situations A There is no CIE device or no compatible CIE device in the network the indicator flashes red twice B There is a compatible CIE device in the...

Page 7: ...powered on for 5 minutes After ZA01B is powered on for 48 hours it will reach the best sensitivity Gas detecting range 500 10000ppm 4 6 Announce Press and hold the Test Key for 3 seconds to announce...

Page 8: ...e Client side EP 0x01 Device ID 0x0402 Basic 0x0000 Identify 0x0003 IAS Zone 0x0500 Commissioning 0x0015 This lists the attributes of the basic information Identifier Name Type Range Access Default Ma...

Page 9: ...0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x04 M 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write O...

Page 10: ...not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or sh...