Page 137/ 191
Recording Mode
As it is not required to record all available image sources at the same time (only the source used
for navigation), the NW6000 allows two methods for recording sources of the same type.
1.
DEFAULT:
Devices with the same type are recorded in round-robin. For two sources of
ECDIS source 1 is recorded first and then source 2 when it arrives in the following time slot.
Thus, every 30s both are recorded.
2.
ALWAYS:
In this case all sources regardless of type are always recorded. So, in the
previous example both ECDIS images received in a time slot will be recorded.
SAVE settings to the VDR using the Save page.
Source type: this defines the type of image source that is transmitting the message. In line
with the VDR performance standard, as a minimal requirement the VDR shall record ECDIS,
SBAND and XBAND radar images.
Configuration is only possible when the VDR is under maintenance, and the service engineer
will have to login using the provided password during training and certification.