Page 27/ 191
2.3 Interfacing
Provided sensors are connected and configured to be recorded. Th following (minimum) data is
stored (line numbers refer to IEC61996-1:2013).
4.6.1 Date and time
4.6.2 Ship’s position
4.6.3 Speed
4.6.4 Heading
4.6.5 Bridge audio
4.6.6 Communications audio
4.6.7 Radar data
4.6.8 ECDIS
4.6.9 Echo sounder
4.6.10 Main CAUTIONs
4.6.11 Rudder order and response
4.6.12 Engine and thruster order and response
4.6.13 Hull openings (doors) status
4.6.14 Watertight and fire door status
4.6.15 Accelerations and hull stresses
4.6.16 Wind speed and direction
4.6.17 AIS
4.6.18 Rolling motion
4.6.19 Configuration data
2.4 Power failure
All available data is recorded until ship’s power to the VDR fails, and from then only selected data
(bridge audio) is recorded for a further two hours after which recording stops automatically.
2.5 Network protocols and IP address ranges incl. LWE
Network protocol requirements.
The VDR implements IPv4 and supports for the following specific network protocols:
•
ARP
– Address Resolution Protocol
•
IP
– Internet Protocol
•
UDP
– User datagram Protocol
•
ICMP
– Internet Control Message Protocol
Summary of Contents for NW6000
Page 1: ......
Page 91: ...Page 91 191...
Page 92: ...Page 92 191...
Page 120: ...Page 120 191 Figure 17 4 2 Connection figure Digital Module 16 channels...
Page 121: ...Page 121 191 Figure 17 4 3 Connection figure Digital Module 24 channels...
Page 125: ...Page 125 191 Figure 18 4 2 Connection figure Analogue Module 8 channels...
Page 126: ...Page 126 191 Figure 18 4 3 Connection figure Analogue Module 12 channels...
Page 184: ...Page 184 191 Figure 5 8 1 Sample dataset playback...