Page 57/ 191
8.
Press the ‘Add’ button and in the “Service Settings” window:
i. Enter
Video TCP
in the ‘Description of service’ field.
ii. Enter
192.168.199.228
in the ‘Name or IP address’ field.
iii. Enter
3659
in the ‘External Port number for this service’ field.
iv. Enter
3659
in the ‘Internal Port number for this service’ field.
v. Select the
TCP
radio button.
vi.
Press ‘OK’.
Press the ‘Add’ button and in the
Service Settings
window:
1.
Description of service:
Enter Video UDP
2.
Name or IP address’:
Enter 192.168.199.228
3.
External Port number for this service:
Enter
2649
4.
Internal Port number for this service:
Enter
2649
5.
Select the
UDP
radio button.
6.
Press ‘OK’.
a)
Press OK in the
Advanced Settings
window.
b)
Press OK in the
Windows Firewall
window.
c)
Press ‘Close’ in the Local Area Connection Properties window.
d)
Install VCS2 on the Service PC.
e)
Run VCS2 on the service PC.
10.9 Configuration
The required video capture interval is 15 seconds (4 images per minute) for each video source.
The Core Module initiates the capture of video information and specifies its configuration. This
includes:
▪
the video channel to be digitized.
▪
the sources of the vertical and horizontal syncs.
▪
the coefficients for the Phase Locked Loop (PLL) -generated pixel clock (or selection of
an external clock); and
▪
the dimensions (number of samples and lines) of the captured frame.
The video capture can be configured using the Video Configuration suite.
▪
Edit the <
VidChanX.ini>
file for each video source.
Summary of Contents for NW6000
Page 1: ......
Page 91: ...Page 91 191...
Page 92: ...Page 92 191...
Page 120: ...Page 120 191 Figure 17 4 2 Connection figure Digital Module 16 channels...
Page 121: ...Page 121 191 Figure 17 4 3 Connection figure Digital Module 24 channels...
Page 125: ...Page 125 191 Figure 18 4 2 Connection figure Analogue Module 8 channels...
Page 126: ...Page 126 191 Figure 18 4 3 Connection figure Analogue Module 12 channels...
Page 184: ...Page 184 191 Figure 5 8 1 Sample dataset playback...